Automatic Fire Suppression System

Intelligent protection that works even without electricity

What is Firetrace?

​Firetrace is a revolutionary automatic fire suppression system designed for enclosed spaces and equipment. What makes it unique is its fully pneumatic operation – it requires no electricity, no batteries, and no external power to detect and suppress fires.

The Innovation

Traditional fire suppression systems depend on electrical power, smoke detectors, control panels, and manual activation. Firetrace needs none of these. It's a self-contained, pressure-driven system that activates automatically when it detects heat or flame – even during complete power outages


How Firetrace Works

Direct Release Systems

Indirect Release Systems

The Detection Tube

At the heart of Firetrace is a proprietary pressurized detection tube installed inside the protected enclosure:

  • The tube acts as both detector and actuator

  • Filled with pressurized gas (around 15 bar)

  • Heat-sensitive polymer that ruptures at 120°C (248°F) or upon flame contact

  • Rupture occurs at the point closest to the fire



Instant Activation

When the tube ruptures:

  • Pressure drop detected immediately

  • Main valve opens (pneumatic/mechanical)

  • Suppression agent releases

  • Fire extinguished in seconds

Total response time: 3–10 seconds from detection to suppression




System Types

Direct Release Systems

How it works: In a direct release system, the suppressant will come through the hole in the tube directly.



Common applications: Direct release systems are recommended for electrical panel and server rack protection.


Key benefits: The direct release system works well for protection of electrical hazards, because it does not rely on any metal components installed within an electrical enclosure. Metal components, like nozzles, can cause electrical arc faults, which actually increase your fire risk. Because direct release systems rely entirely on the tubing, a plastic material, fire risk is reduced.

Indirect Release Systems

How it works: An indirect release is when the tube acts as a detection device and, through the pressure change, tells the system to discharge the agent through other pipes and nozzles.


Common applications: Indirect release systems are commonly used for vehicles and in CNC machines.


Key benefits: Firetrace Indirect Release Systems have been independently tested and evaluated by the leading product performance testing agencies. They are UL Listed and FM Approved. Third party testing ensures that products consistently perform as expected and can tolerate environmental challenges like temperature change. Local and national fire codes, including those published by the National Fire Protection Association (NFPA) often recommend UL or FM approved systems. 

Firetrace Works

Firetrace Works in real life


Suppression Agents

Firetrace supports multiple extinguishing agents depending on the fire risk:


01

Clean Agents 

(FK-5-1-12 /

 Novec 1230)

  • Type: Fluorinated ketone

  • Residue: Zero – evaporates completely

  • Electrical safety: 100% safe for electronics

  • Environmental: Low GWP, zero ODP

  • Best for: Data centers, telecom rooms, control rooms, museums

 

02

Firetrace

HFC-227ea 

(Clean Agent)

  • Type: Clean Agent (HFC-227ea)
  • Mechanism: Automatically releases HFC-227ea upon fire detection, extinguishing fires within 10 seconds
  • Best for: Electrical cabinets, machinery, and enclosed equipment
  • Special: No residue and safe for electronics


03

Dry Chemical 

(ABC / BC Powder)

  • Type: Mono-ammonium phosphate or sodium bicarbonate

  • Mechanism: Chain reaction interruption

  • Effectiveness: Excellent for flammable liquid fires

  • Best for: Industrial machinery, paint booths, kitchens

  • Note: Requires cleanup after discharge

 

04

CO₂ 

(Carbon Dioxide)

  • Type: Inert gas

  • Mechanism: Oxygen displacement

  • Effectiveness: Excellent for deep-seated fires

  • Best for: Engine rooms, generators, unmanned spaces

  • Caution: Not for occupied areas

 


Why Firetrace?

1

 Work with or without electricity

    • No batteries
    • no backup power

    • Always active—even during power outages
2

Pinpoint Fire Detection

    • Fire suppressed at the exact source

    • Heat-sensitive tube bursts at hottest point

    • Immediate response, no wasted agent
3

Simple & Reliable

    • No control panels
    • No wiring or programming
    • Purely mechanical = highly reliable



4

Cost-Effective

    • Fast installation (hours, not days)
    • No electrical work required
    • Lower installation and maintenance costs
5

Easy Maintenance

    • System status visible at a glance
    • Simple pressure gauge monitoring
    • Only visual inspection required
6

ZERO Operational Risk

    • Always-on protection 24/7
    • Long service life (20+ years)
    • Proven reliability for critical equipment

International Certifications

Firetrace holds approvals from the world's most demanding certification bodies:
  • UL Listed (USA) – Underwriters Laboratories
  • ULC Listed (Canada) – Underwriters Laboratories of Canada
  • FM Approved (Global) – Factory Mutual
  • CE Marked (Europe) – European Conformity
  • VdS Approved (Germany)
  • LPCB Approved (UK) – Loss Prevention Certification Board

Proven Applications

1

Industrial Machinery

    • CNC Machines & Machining Centers

    • EDM (Electrical Discharge Machining)


2

Electrical Infrastructure

    • Switchgear & Control Panels

    • UPS & Battery Rooms

    • Transformer Enclosures





3

Mobile Equipment

    • Heavy Machinery

    • Public Transportation

    • cars and airplanes







4

Renewable Energy

    • Wind Turbines



5

Commercial Kitchens

    • Restaurant Equipment




Contact Us

6

Data Centers & Server Rooms

    • Protects server cabinets, network racks, and critical IT infrastructure from fire damage with clean agent suppression.



Major Projects by SAMS

Installation & Commissioning


Professional Installation by SAMS

Design Services, Installation, Commissioning, and Training provided by certified and factory-trained professionals in full compliance with local codes.


Maintenance & Support


Annual Maintenance

Visual inspection, functional tests, and pressure monitoring.

Typical service frequency: Once per year


24/7 Emergency Support

Emergency response team, spare parts inventory, on-site cylinder recharge, system restoration services.


System Recharge

Typical recharge time: 1–2 hours


Technical Specifications

ItemSpecification
Detection Tube MaterialProprietary polymer blend
Tube Pressure15 bar (217 psi)
Activation Temperature120°C ± 5°C
Detection Tube Service Life20+ years
Operating Temperature Range-40°C to +120°C
Cylinder Sizes2 to 200 lbs
Valve ActuationPneumatic / Pneumatic-Electric


Why Choose SAMS for Firetrace?

Exclusive authorized partner, extensive experience, expert team, full-service capability, and guaranteed compliance.